Product Overview
A positive antibody result supports assessment of exposure. Interpret it alongside the animal’s clinical history and other findings. Check the dog or cat kit label when selecting the shipping format.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation
- TOXO Ab
- Species
- Dog, cat
- Specimen
- Whole blood, serum or plasma
- Sample loading
- 1 drop of sample (about 10 μL), then 2 drops (about 60 μL) of buffer
- Reading time
- 5–10 minutes (results after 15 minutes are invalid)
- Format & pack size
- Cassette, 10 tests
- Storage
- Store sealed at 4–30°C, protected from light. Do not freeze.
- Operating temperature
- 15–30°C
- Shelf Life
- See expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
4 steps from the instructions for use
-
1Prepare the test
Check the expiry date and pouch seal. Work at 15–30°C.
-
2Add the sample
Lay the newly opened cassette flat. Use the capillary dropper to add 1 drop (about 10 μL) of whole blood, serum or plasma to the S well.
-
3Add buffer
Immediately add 2 drops (about 60 μL) of the supplied buffer to the same S well.
-
4Time and read
Start timing after loading. Read at 5–10 minutes. Results read after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare the test Check the expiry date and pouch seal. Work at 15–30°C.
- 2. Add the sample Lay the newly opened cassette flat. Use the capillary dropper to add 1 drop (about 10 μL) of whole blood, serum or plasma to the S well.
- 3. Add buffer Immediately add 2 drops (about 60 μL) of the supplied buffer to the same S well.
- 4. Time and read Start timing after loading. Read at 5–10 minutes. Results read after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use
Check the control line (C) first, then the test line (T).

Positive
Both C and T lines appear. A faint T line within the reading window counts as positive.

Negative
Only the C line appears. The target antibody was not detected in this sample.

Invalid
The C line is absent, regardless of the T line. Repeat with a new cassette.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Sensitivity | Specificity | Overall Agreement |
|---|---|---|---|---|
| TOXO Ab | ELISA | 95.83% 115/120 95% CI 90.37%–98.46% | 97.22% 175/180 95% CI 93.48%–98.99% | 96.67% 290/300 95% CI 93.89%–98.26% |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Capillary droppers
- Buffer
- Instructions for use
Also required
Timer