Product Overview
Record which dog the tick came from and the collection date. A positive tick result provides an exposure clue. The dog’s infection status requires a separate veterinary assessment.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation
- Lyme Ag
- Species
- Dog
- Specimen
- Whole tick removed from a dog
- Sample loading
- 3 drops of mixed tick extract (about 90 μL)
- Reading time
- 5–10 minutes (results after 15 minutes are invalid)
- Format & pack size
- Cassette, 10 tests
- Storage
- Store sealed at 4–30°C, protected from light. Do not freeze.
- Operating temperature
- 15–30°C
- Shelf Life
- See expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
5 steps from the instructions for use
-
1Prepare the test
Check the expiry date and pouch seal. Work at 15–30°C.
-
2Remove the tick
Use the tick remover to collect the whole tick, including the head. Care for the bite site.
-
3Prepare the tick sample
Place the tick in the sample tube and crush it with the rod. Set the tube in its rack, empty the supplied buffer into the tube, cap and shake thoroughly.
-
4Load the cassette
Open the pouch and lay the cassette on a clean, level surface. Add 3 drops of mixed tick extract (about 90 μL) to the S well.
-
5Time and read
Start timing after loading. Read at 5–10 minutes. Results read after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare the test Check the expiry date and pouch seal. Work at 15–30°C.
- 2. Remove the tick Use the tick remover to collect the whole tick, including the head. Care for the bite site.
- 3. Prepare the tick sample Place the tick in the sample tube and crush it with the rod. Set the tube in its rack, empty the supplied buffer into the tube, cap and shake thoroughly.
- 4. Load the cassette Open the pouch and lay the cassette on a clean, level surface. Add 3 drops of mixed tick extract (about 90 μL) to the S well.
- 5. Time and read Start timing after loading. Read at 5–10 minutes. Results read after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use
Check the control line (C) first, then the test line (T).

Positive
Both C and T lines appear. A faint T line within the reading window counts as positive.

Negative
Only the C line appears. The target antigen was not detected in this sample.

Invalid
The C line is absent, regardless of the T line. Repeat with a new cassette.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Buffer
- Tick remover
- Sample tube
- Crushing rod
- Tube rack
- Instructions for use
Also required
Timer