Sabervet H.pylori Antigen Rapid Test
Product Overview
Sabervet H.pylori Antigen Rapid Test (HP Ag) is a versatile lateral flow immunoassay for B2B veterinary clients, designed to qualitatively detect Helicobacter pylori antigens in fresh canine or feline feces or rectal swab samples. Aiding HP infection diagnosis, it offers 97.97% positive agreement and 96.97% negative agreement, with results available in 5-10 minutes. The kit includes test devices, swabs, buffer tubes, workstation, and a package insert, supporting simple sample collection and testing. Stored away from light at 4-30℃ (no freezing), it maintains stability until the expiry date. Compliant with safety regulations, it’s suitable for animal hospitals, clinics, and diagnostic labs seeking non-invasive, efficient screening for canine and feline HP infections without complex equipment.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation
- HP Ag
- Species
- Dog, cat
- Targets
- Helicobacter pylori antigen
- Method
- Immunochromatographic qualitative test
- Specimen
- Fresh feces or rectal swab
- Pack size
- 10 tests per box
- Sample volume
- 3 drops of extracted mixture (about 90 μL)
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Storage & test temperature
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
5 steps from the instructions for use
-
1Prepare the buffer
Open the buffer tube and place it in the workstation.
-
2Collect the sample
Swab a small amount of fresh feces or collect a rectal sample, then place the swab in the buffer.
-
3Extract the sample
Rotate the swab in the buffer more than 10 times, then close the dropper cap.
-
4Sample loading
Lay the cassette flat and add 3 drops of the mixture (about 90 μL) to the S well.
-
5
Time and read
Start timing after loading; read and record at 5–10 minutes. Results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare the buffer Open the buffer tube and place it in the workstation.
- 2. Collect the sample Use the swab provided to take a small amount of fresh feces, or have trained staff collect a rectal sample; then place the swab in the buffer.
- 3. Extract the sample Rotate the swab in the buffer tube more than 10 times to release the sample; remove the swab and close the tube with the dropper cap.
- 4. Sample loading Open the foil pouch and lay the cassette on a clean, level surface. Add 3 drops of the mixture (about 90 μL) vertically into the S well.
- 5. Time and read Start timing after loading; read and record at 5–10 minutes. Results after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use

Positive
Both C and T lines appear; a faint T line is also positive.

Negative
Only the C line appears: the antigen was not detected at the test's detection level; this alone does not exclude gastric problems.

Invalid
No C line appears: invalid whether or not a T line appears. Check sample processing, loading, storage and expiry date, then retest with a new cassette.
Interpretation notes
- Invalid: No C line appears: invalid whether or not a T line appears. Check sample processing, loading, storage and expiry date, then retest with a new cassette. Line intensity is not used to estimate bacterial load or severity. A negative result after treatment does not by itself prove eradication.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| HP Ag | PCR | 97.97% 145/148 | 96.97% 192/198 | 97.40% 337/346 |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Sampling swabs
- Buffer tubes
- Instructions for use
- Workstation
Also required
Timer