SaberVet Feline Toxoplasma Antibody Rapid Test
Product Parameters
Engineered for precision, built for reliability
- Abbreviation & species
- TOXO Ab; cat
- Targets
- Toxoplasma antibodies (IgM/IgG not reported separately)
- Method & specimen
- Lateral flow immunoassay; whole blood, serum or plasma
- Sample loading
- 1 drop of sample (about 10 μL), then 2 drops of buffer (about 60 μL), into the same S well
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Pack size
- 10 tests per box
- Storage & operation
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
Clear Results, Confident Diagnosis
Eliminate diagnostic uncertainty with our advanced colloidal gold technology that delivers crystal-clear test lines and reliable results every time.
SaberVet Advantage
- Deep red, crystal-clear T-lines
- Clean, interference-free background
- GMP-controlled batch consistency
- Confident, reliable diagnosis
Test Procedure
4 steps from the instructions for use
-
1
Prepare
Work at 15–30°C and lay the cassette flat right after opening.
-
2Add the blood sample
Use the dropper to add 1 drop (about 10 μL) of whole blood, serum or plasma to the S well.
-
3Add the buffer
Immediately add 2 drops of buffer (about 60 μL) to the same S well, then start timing.
-
4
Read and record
Keep the cassette level; read and record within 5–10 minutes. Results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare Check the sample ID, lot, expiry date, packaging and components, and work at 15–30°C. Let refrigerated kits reach operating temperature before opening the pouch, then lay the cassette flat right after opening.
- 2. Add the blood sample Use the dropper provided to add 1 drop (about 10 μL) of whole blood, serum or plasma to the S well. Use separate consumables for each cat and do not pool samples.
- 3. Add the buffer Immediately add 2 drops of the buffer provided (about 60 μL) to the same S well, then start timing. Do not reverse the order, premix or keep adding drops.
- 4. Read and record Keep the cassette level; read and record within 5–10 minutes. Results after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use

Positive
Both colored C and T lines appear; a faint T line within the reading time is also positive.

Negative
Only the C line appears: the antibodies were not detected at the test's detection level; early infection or a weak immune response can still give a negative result.

Invalid
No C line appears: invalid whatever the T zone shows. Check the sample, loading and storage/transport, then retest with a new cassette.
Interpretation notes
- Positive: Both colored C and T lines appear; a faint T line within the reading time is also positive. This indicates an antibody response and does not establish when infection occurred, disease severity or current oocyst shedding.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| TOXO Ab | ELISA | 95.83% 115/120 95% CI 90.37%–98.46% | 97.22% 175/180 95% CI 93.48%–98.99% | 96.67% 290/300 95% CI 93.89%–98.26% |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Droppers
- Buffer
- Instructions for use
Also required
Timer, suitable blood collection supplies, sample containers and personal protective equipment