SaberVet Logo
FPV_FCoV Ag
GMP Certified
A Specialized Brand by ITGen

Sabervet Feline Panleukopenia Virus/Coronavirus Antigen Combo Rapid Test

Sabervet’s FPV+FCoV Antigen Combo Test allows for the simultaneous detection of Feline Panleukopenia and Coronavirus antigens in fresh feces or rectal swabs. Results in 5–10 minutes with high accuracy, ideal for feline enteric disease screening.
Specimen
Fresh feces or rectal swab
Pack Size
10 tests (10 dual-test cassettes per box)
Reading Time
5–10 minutes
Shelf Life
See the expiration date on the package.

Product Overview

This combo rapid test is designed for the simultaneous qualitative detection of FPV and FCoV antigens in feline fecal samples. With positive agreement of 98.00% for FPV and 98.50% for FCoV, it provides a reliable diagnostic tool for veterinary clinics. The test is user-friendly, with clear visual results available within minutes, supporting prompt diagnosis and treatment.

Technical Data

Product Parameters

Engineered for precision, built for reliability

Abbreviation & species
FPV/FCoV Ag; cat
Targets
Feline panleukopenia virus antigen, feline coronavirus antigen
Specimen
Fresh feces or rectal swab
Sample loading
3 drops of extract (about 90 μL) into each S well
Reading time
5–10 minutes; results after 15 minutes are invalid
Pack size
10 tests (10 dual-test cassettes per box)
Storage & operating temperature
Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
Shelf Life
See the expiration date on the package.
Certifications
CE, ISO 13485 & GMP certified
OEM/ODM Service
Available

Test Procedure

5 steps from the instructions for use

  1. Step 1: Prepare the buffer
    1

    Prepare the buffer

    At 15–30°C, check the packaging, expiry date and sample ID. Open the buffer tube and place it in the workstation.

  2. Step 2: Collect the sample
    2

    Collect the sample

    Use the swab provided to collect a small amount of fresh feces or a rectal fecal sample, then place the swab in the buffer.

  3. Step 3: Extract the sample
    3

    Extract the sample

    Rotate the swab in the buffer more than 10 times to release the sample, then close the cap.

  4. Step 4: Load both wells
    4

    Load both wells

    Add 3 drops of extract (about 90 μL) to each of the FPV and FCoV wells, then start timing.

  5. 5

    Read and record

    Read the FPV and FCoV windows separately within 5–10 minutes. Results after 15 minutes are invalid.

Full step-by-step instructions
  1. 1. Prepare the buffer At 15–30°C, check the packaging, expiry date and sample ID. Open the buffer tube and place it in the workstation.
  2. 2. Collect the sample Use the swab provided to collect a small amount of fresh feces or a rectal fecal sample, then place the swab in the buffer.
  3. 3. Extract the sample Rotate the swab in the buffer more than 10 times to release the sample, then close the cap.
  4. 4. Load both wells Lay the cassette flat right after opening. Add the same extract vertically into the FPV and FCoV S wells, 3 drops (about 90 μL) per well, 6 drops in total. Start timing after loading each unit and do not skip either well.
  5. 5. Read and record Read the FPV and FCoV windows separately within 5–10 minutes, checking the C line first and then the T line, and record both results. Results after 15 minutes are invalid.

Reading the Results

Read within the time stated in the instructions for use

The line patterns below apply to each of the two test units; match FPV and FCoV to the labels on the cassette.

Positive result

Positive

Both C and T lines appear in that unit; any visible T line is positive.

Negative result

Negative

Only the C line appears in that unit: the detection level was not reached in this sample; low antigen load or sampling effects cannot be excluded.

Invalid result

Invalid

No C line in that unit: invalid whether or not a T line appears.

Interpretation notes
  • Invalid: No C line in that unit: invalid whether or not a T line appears. Read the two units separately and retest an invalid item with a new cassette; repeat the test if both windows or the overall flow are abnormal.

Performance Data

Method comparison results stated in the instructions for use

Target Reference Method Positive AgreementNegative AgreementOverall Agreement
FPV PCR 98.00% 147/150 95% CI 94.29%–99.32% 97.50% 195/200 95% CI 94.28%–98.93% 97.71% 342/350 95% CI 95.56%–98.84%
FCoV PCR 98.50% 197/200 95% CI 95.68%–99.49% 97.33% 146/150 95% CI 93.34%–98.96% 98.00% 343/350 95% CI 95.93%–99.03%

Each target is evaluated separately against its reference method; the results are not combined into a single accuracy figure for the whole test.

Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.

Kit Contents

What is supplied in each box and what you need to prepare

Sabervet Feline Panleukopenia Virus/Coronavirus Antigen Combo Rapid Test kit components

Included in the kit

  • Dual-test cassettes
  • Sampling swabs
  • Buffer tubes
  • Instructions for use
  • Workstation

Also required

Timer, gloves, sample labels and waste container

Request Information