Product Overview
The SaberVet FPV Ag Test is a professional-grade lateral flow immunoassay for the qualitative detection of Feline Panleukopenia Virus. It offers high diagnostic sensitivity and specificity, providing results within 10 minutes to support early clinical intervention.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation & species
- FPV Ag; cat
- Target & method
- Feline panleukopenia virus antigen; colloidal gold immunochromatography, qualitative
- Specimen
- Fresh feces or rectal swab
- Sample loading
- 3 drops of extracted mixture (about 90 μL)
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Pack size
- 10 tests per box
- Storage & operation
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
6 steps from the instructions for use
-
1Prepare the buffer
Open the seal of the buffer tube and place it in the workstation.
-
2Collect the sample
Use the swab provided to collect fresh feces or a rectal fecal sample. Use a separate swab and extraction tube for each cat.
-
3Extract thoroughly
Place the swab in the buffer and rotate more than 10 times to release the sample.
-
4Close the cap
Close the buffer tube cap, ready to dispense the extract.
-
5Load and time
Lay the cassette flat, add 3 drops of the mixture (about 90 μL) to the S well and start timing.
-
6
Read the result
Read and record within 5–10 minutes. Results after 15 minutes are invalid; dispose of the used cassette, swab and extract as contaminated waste.
Full step-by-step instructions
- 1. Prepare the buffer Open the seal of the buffer tube and place it in the workstation.
- 2. Collect the sample Use the swab provided to collect fresh feces or a rectal fecal sample. Use a separate swab and extraction tube for each cat.
- 3. Extract thoroughly Place the swab in the buffer and rotate more than 10 times to release the sample.
- 4. Close the cap Close the buffer tube cap, ready to dispense the extract.
- 5. Load and time Lay the cassette on a clean, level surface, add 3 drops of the mixture (about 90 μL) vertically into the S well and start timing.
- 6. Read the result Read and record within 5–10 minutes. Results after 15 minutes are invalid; dispose of the used cassette, swab and extract as contaminated waste.
Reading the Results
Read within the time stated in the instructions for use

Positive
Both colored C and T lines appear.

Negative
Only the C line appears: the antigen was not detected at the test's detection level; a suspected case should not be released from isolation on a single negative result.

Invalid
No C line appears: the result is invalid with or without a T line.
Interpretation notes
- Positive: Both colored C and T lines appear. A faint T line within the reading time is also positive: the antigen was detected in this sample; interpret with clinical signs and vaccination history.
- Invalid: No C line appears: the result is invalid with or without a T line. Check the sample, loading, timing and storage/transport, then retest with a new cassette.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| FPV Ag | PCR | 98.00% 147/150 95% CI 94.02%–99.58% | 97.50% 195/200 95% CI 94.12%–99.09% | 97.71% 342/350 95% CI 95.48%–98.92% |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Sampling swabs
- Buffer tubes
- Instructions for use
- Workstation
Also required
Timer and personal protective equipment