Product Overview
Specifically developed for monitoring immune status and detecting infection, the SaberVet FPV Ab Rapid Test identifies antibodies to Feline Panleukopenia Virus in blood samples. It is a key tool for veterinarians to verify vaccination efficacy and clinical health.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation & species
- FPV Ab; cat
- Target & method
- Feline panleukopenia virus antibodies; colloidal gold immunochromatography, visual qualitative reading
- Specimen
- Whole blood, serum or plasma
- Sample loading
- 1 drop of blood (about 10 μL), then 2 drops of buffer (about 60 μL) into the same well
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Pack size
- 10 tests per box
- Storage & operation
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
4 steps from the instructions for use
-
1
Prepare
Work at 15–30°C and lay the cassette flat on a clean, level surface right after opening.
-
2Add the blood sample
Use the capillary dropper provided to add 1 drop (about 10 μL) of whole blood, serum or plasma directly to the S well.
-
3Add the buffer
Then add 2 drops of buffer (about 60 μL) to the same S well.
-
4
Time and read
Start timing after loading; read and record within 5–10 minutes. Results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare Work at 15–30°C and check the product, cat ID, lot and expiry date. Check the packaging, take the cassette out right after opening and lay it on a clean, level surface.
- 2. Add the blood sample Use the capillary dropper provided to add 1 drop (about 10 μL) of whole blood, serum or plasma directly to the S well.
- 3. Add the buffer Then add 2 drops of buffer (about 60 μL) to the same S well. Keep the bottle tip away from the sample and cassette; both steps are required.
- 4. Time and read Start timing after loading; read and record within 5–10 minutes. Results after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use

Positive
Both colored C and T lines appear; a faint T line within the reading time is also positive.

Negative
Only the C line appears: the antibodies were not detected at the test's detection level; this cannot exclude acute infection or prove a complete lack of immunity.

Invalid
No C line appears: the result is invalid with or without a T line.
Interpretation notes
- Positive: Both colored C and T lines appear; a faint T line within the reading time is also positive. Antibodies were detected; this does not by itself mean a protective titer or current infection.
- Invalid: No C line appears: the result is invalid with or without a T line. Check the sample, both loading steps, timing and storage/transport, then retest with a new cassette.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| FPV Ab | ELISA | 97.50% 195/200 95% CI 94.12%–99.09% | 96.00% 96/100 95% CI 89.84%–98.76% | 97.00% 291/300 95% CI 94.31%–98.50% |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Capillary droppers
- Buffer
- Instructions for use
Also required
Timer, blood collection supplies and personal protective equipment