Sabervet Feline Panleukopenia Virus Antibody Rapid Test

Qualitative detection of Feline Panleukopenia Virus (FPV) antibodies.
Positive Agreement
97.50%
Negative Agreement
96.00%
Reading Time
5–10 minutes
Shelf Life
See the expiration date on the package.

Product Overview

Specifically developed for monitoring immune status and detecting infection, the SaberVet FPV Ab Rapid Test identifies antibodies to Feline Panleukopenia Virus in blood samples. It is a key tool for veterinarians to verify vaccination efficacy and clinical health.

Technical Data

Product Parameters

Engineered for precision, built for reliability

Abbreviation & species
FPV Ab; cat
Target & method
Feline panleukopenia virus antibodies; colloidal gold immunochromatography, visual qualitative reading
Specimen
Whole blood, serum or plasma
Sample loading
1 drop of blood (about 10 μL), then 2 drops of buffer (about 60 μL) into the same well
Reading time
5–10 minutes; results after 15 minutes are invalid
Pack size
10 tests per box
Storage & operation
Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
Shelf Life
See the expiration date on the package.
Certifications
CE, ISO 13485 & GMP certified
OEM/ODM Service
Available

Test Procedure

4 steps from the instructions for use

  1. 1

    Prepare

    Work at 15–30°C and lay the cassette flat on a clean, level surface right after opening.

  2. Step 2: Add the blood sample
    2

    Add the blood sample

    Use the capillary dropper provided to add 1 drop (about 10 μL) of whole blood, serum or plasma directly to the S well.

  3. Step 3: Add the buffer
    3

    Add the buffer

    Then add 2 drops of buffer (about 60 μL) to the same S well.

  4. 4

    Time and read

    Start timing after loading; read and record within 5–10 minutes. Results after 15 minutes are invalid.

Full step-by-step instructions
  1. 1. Prepare Work at 15–30°C and check the product, cat ID, lot and expiry date. Check the packaging, take the cassette out right after opening and lay it on a clean, level surface.
  2. 2. Add the blood sample Use the capillary dropper provided to add 1 drop (about 10 μL) of whole blood, serum or plasma directly to the S well.
  3. 3. Add the buffer Then add 2 drops of buffer (about 60 μL) to the same S well. Keep the bottle tip away from the sample and cassette; both steps are required.
  4. 4. Time and read Start timing after loading; read and record within 5–10 minutes. Results after 15 minutes are invalid.

Reading the Results

Read within the time stated in the instructions for use

Positive result

Positive

Both colored C and T lines appear; a faint T line within the reading time is also positive.

Negative result

Negative

Only the C line appears: the antibodies were not detected at the test's detection level; this cannot exclude acute infection or prove a complete lack of immunity.

Invalid result

Invalid

No C line appears: the result is invalid with or without a T line.

Interpretation notes
  • Positive: Both colored C and T lines appear; a faint T line within the reading time is also positive. Antibodies were detected; this does not by itself mean a protective titer or current infection.
  • Invalid: No C line appears: the result is invalid with or without a T line. Check the sample, both loading steps, timing and storage/transport, then retest with a new cassette.

Performance Data

Method comparison results stated in the instructions for use

Target Reference Method Positive AgreementNegative AgreementOverall Agreement
FPV Ab ELISA 97.50% 195/200 95% CI 94.12%–99.09% 96.00% 96/100 95% CI 89.84%–98.76% 97.00% 291/300 95% CI 94.31%–98.50%

Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.

Kit Contents

What is supplied in each box and what you need to prepare

Sabervet Feline Panleukopenia Virus Antibody Rapid Test kit components

Included in the kit

  • Test cassettes
  • Capillary droppers
  • Buffer
  • Instructions for use

Also required

Timer, blood collection supplies and personal protective equipment

Request Information

Submitting...