Product Overview
Support your clinic’s infectious disease management with the SaberVet FeLV Ag Rapid Test. This lateral flow immunoassay identifies Feline Leukemia Virus antigens in whole blood or plasma, delivering clear, actionable results within 10 minutes.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation & species
- FeLV Ag; cat
- Target & method
- Feline leukemia virus antigen; lateral flow immunoassay, visual qualitative reading
- Specimen
- Whole blood, serum or plasma
- Sample loading
- 1 drop of sample (about 10 μL), then 2 drops of buffer (about 60 μL) into the same well
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Pack size
- 10 tests per box
- Storage & operation
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
4 steps from the instructions for use
-
1
Prepare
Bring the kit and sample to 15–30°C and lay the cassette flat right after opening.
-
2Add the sample
Use the capillary dropper provided to add 1 drop (about 10 μL) of whole blood, serum or plasma directly to the S well.
-
3Add the buffer
Immediately add 2 drops of buffer (about 60 μL) to the same S well.
-
4
Time and read
Start timing after loading; read, record and photograph within 5–10 minutes. Results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare Bring the cassette, buffer and sample to 15–30°C. Check the cat ID, lot and expiry date and that the foil pouch is intact. Lay the cassette on a clean, level surface right after opening.
- 2. Add the sample Use the capillary dropper provided to add 1 drop (about 10 μL) of whole blood, serum or plasma directly to the S well.
- 3. Add the buffer Immediately add 2 drops of the buffer provided (about 60 μL) to the same S well, keeping the bottle tip away from the sample and cassette.
- 4. Time and read Start timing after loading; read, record and photograph within 5–10 minutes. Results after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use

Positive
Both C and T lines appear. A faint colored T line within the reading time is also positive; confirm further with clinical findings.

Negative
Only the C line appears: the antigen was not detected at the test's detection level; retest after recent exposure or when infection is strongly suspected.

Invalid
No C line appears: invalid with or without a T line. Check the sample, procedure and storage/transport, then retest with a new cassette.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| FeLV Ag | PCR | 97.78% 176/180 95% CI 94.43%–99.13% | 97.06% 165/170 95% CI 93.30%–98.74% | 97.43% 341/350 95% CI 95.19%–98.64% |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Capillary droppers
- Buffer
- Instructions for use
Also required
Timer, suitable blood collection supplies and personal protective equipment