SaberVet Feline Immunodeficiency Virus Antibody/Leukemia Virus Antigen Combo Rapid Test
Product Parameters
Engineered for precision, built for reliability
- Targets
- FeLV antigen; FIV antibody
- Species & specimen
- Cat; whole blood, serum or plasma
- Loading per well
- 1 drop of sample (about 10 μL), then 2 drops of buffer (about 60 μL), in each of the two S wells
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Pack size
- 10 tests per box (10 dual-test cassettes)
- Storage & operation
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
Clear Results, Confident Diagnosis
Eliminate diagnostic uncertainty with our advanced colloidal gold technology that delivers crystal-clear test lines and reliable results every time.
SaberVet Advantage
- Deep red, crystal-clear T-lines
- Clean, interference-free background
- GMP-controlled batch consistency
- Confident, reliable diagnosis
Test Procedure
5 steps from the instructions for use
-
1
Prepare
At 15–30°C, lay the cassette flat and identify the FeLV and FIV wells.
-
2Draw the blood sample
Use the capillary dropper provided to draw whole blood, serum or plasma from the same cat, avoiding bubbles and contamination.
-
3Add sample to both wells
Add 1 drop of sample (about 10 μL) to each of the FeLV and FIV S wells.
-
4Add buffer to each well
Then add 2 drops of buffer (about 60 μL) to each of the two S wells and start timing.
-
5
Read and record
Check the two windows separately within 5–10 minutes and record the FeLV antigen and FIV antibody results; results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare Check the expiry date and packaging, and bring samples and reagents to 15–30°C. Lay the cassette flat on a clean bench right after opening and identify the FeLV and FIV S wells.
- 2. Draw the blood sample Use the capillary dropper provided to draw whole blood, serum or plasma from the same cat, avoiding bubbles and contamination.
- 3. Add sample to both wells Add 1 drop of sample (about 10 μL) to each of the FeLV and FIV S wells.
- 4. Add buffer to each well Then add 2 drops of the buffer provided (about 60 μL) to each of the same two S wells. Do not premix. Start timing after each well is done.
- 5. Read and record Check the two windows separately within 5–10 minutes and record the FeLV antigen and FIV antibody results; results after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use
Each of the two windows has its own C and T lines and is read separately.

Positive
Both C and T lines appear; a faint T line is also positive. The FeLV window indicates antigen detected; the FIV window indicates antibody detected.

Negative
Only the C line appears: the item did not reach the detection level in this sample; interpret with the time since exposure and other information.

Invalid
No C line appears: that item is invalid whether or not a T line appears and must be retested with a new cassette.
Interpretation notes
- Invalid: No C line appears: that item is invalid whether or not a T line appears and must be retested with a new cassette. Read the other item from its own window and note the partial invalid result; retest if neither window shows a C line.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| FeLV Ag | PCR | 97.78% 176/180 95% CI 94.43%–99.13% | 97.06% 165/170 95% CI 93.30%–98.74% | 97.43% 341/350 95% CI 95.19%–98.64% |
| FIV Ab | ELISA | 96.88% 155/160 95% CI 92.89%–98.66% | 98.13% 157/160 95% CI 94.63%–99.36% | 97.50% 312/320 95% CI 95.15%–98.73% |
Each target is evaluated separately against its reference method; the results are not combined into a single accuracy figure for the whole test.
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Dual-test cassettes
- Capillary droppers
- Buffer
- Instructions for use
Also required
Timer, gloves, sample labels and waste container