SaberVet Logo
SaberVet Feline Immunodeficiency Virus Antibody/Leukemia Virus Antigen Combo Rapid Test
GMP Certified
A Specialized Brand by ITGen

SaberVet Feline Immunodeficiency Virus Antibody/Leukemia Virus Antigen Combo Rapid Test

Rapid qualitative detection of FeLV antigen and FIV antibody in feline whole blood, serum or plasma. Two independent windows give separate results, so both important feline retroviruses can be checked in one visit or health assessment.
Specimen
Whole blood, serum or plasma
Pack Size
10 tests per box (10 dual-test cassettes)
Reading Time
5–10 minutes
Technical Data

Product Parameters

Engineered for precision, built for reliability

Targets
FeLV antigen; FIV antibody
Species & specimen
Cat; whole blood, serum or plasma
Loading per well
1 drop of sample (about 10 μL), then 2 drops of buffer (about 60 μL), in each of the two S wells
Reading time
5–10 minutes; results after 15 minutes are invalid
Pack size
10 tests per box (10 dual-test cassettes)
Storage & operation
Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C

Clear Results, Confident Diagnosis

Eliminate diagnostic uncertainty with our advanced colloidal gold technology that delivers crystal-clear test lines and reliable results every time.

SaberVet Advantage

Clear SaberVet test results
  • Deep red, crystal-clear T-lines
  • Clean, interference-free background
  • GMP-controlled batch consistency
  • Confident, reliable diagnosis

Test Procedure

5 steps from the instructions for use

  1. 1

    Prepare

    At 15–30°C, lay the cassette flat and identify the FeLV and FIV wells.

  2. Step 2: Draw the blood sample
    2

    Draw the blood sample

    Use the capillary dropper provided to draw whole blood, serum or plasma from the same cat, avoiding bubbles and contamination.

  3. Step 3: Add sample to both wells
    3

    Add sample to both wells

    Add 1 drop of sample (about 10 μL) to each of the FeLV and FIV S wells.

  4. Step 4: Add buffer to each well
    4

    Add buffer to each well

    Then add 2 drops of buffer (about 60 μL) to each of the two S wells and start timing.

  5. 5

    Read and record

    Check the two windows separately within 5–10 minutes and record the FeLV antigen and FIV antibody results; results after 15 minutes are invalid.

Full step-by-step instructions
  1. 1. Prepare Check the expiry date and packaging, and bring samples and reagents to 15–30°C. Lay the cassette flat on a clean bench right after opening and identify the FeLV and FIV S wells.
  2. 2. Draw the blood sample Use the capillary dropper provided to draw whole blood, serum or plasma from the same cat, avoiding bubbles and contamination.
  3. 3. Add sample to both wells Add 1 drop of sample (about 10 μL) to each of the FeLV and FIV S wells.
  4. 4. Add buffer to each well Then add 2 drops of the buffer provided (about 60 μL) to each of the same two S wells. Do not premix. Start timing after each well is done.
  5. 5. Read and record Check the two windows separately within 5–10 minutes and record the FeLV antigen and FIV antibody results; results after 15 minutes are invalid.

Reading the Results

Read within the time stated in the instructions for use

Each of the two windows has its own C and T lines and is read separately.

Positive result

Positive

Both C and T lines appear; a faint T line is also positive. The FeLV window indicates antigen detected; the FIV window indicates antibody detected.

Negative result

Negative

Only the C line appears: the item did not reach the detection level in this sample; interpret with the time since exposure and other information.

Invalid result

Invalid

No C line appears: that item is invalid whether or not a T line appears and must be retested with a new cassette.

Interpretation notes
  • Invalid: No C line appears: that item is invalid whether or not a T line appears and must be retested with a new cassette. Read the other item from its own window and note the partial invalid result; retest if neither window shows a C line.

Performance Data

Method comparison results stated in the instructions for use

Target Reference Method Positive AgreementNegative AgreementOverall Agreement
FeLV Ag PCR 97.78% 176/180 95% CI 94.43%–99.13% 97.06% 165/170 95% CI 93.30%–98.74% 97.43% 341/350 95% CI 95.19%–98.64%
FIV Ab ELISA 96.88% 155/160 95% CI 92.89%–98.66% 98.13% 157/160 95% CI 94.63%–99.36% 97.50% 312/320 95% CI 95.15%–98.73%

Each target is evaluated separately against its reference method; the results are not combined into a single accuracy figure for the whole test.

Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.

Kit Contents

What is supplied in each box and what you need to prepare

SaberVet Feline Immunodeficiency Virus Antibody/Leukemia Virus Antigen Combo Rapid Test kit components

Included in the kit

  • Dual-test cassettes
  • Capillary droppers
  • Buffer
  • Instructions for use

Also required

Timer, gloves, sample labels and waste container

Request Information

Submitting...