Sabervet Feline Herpesvirus/Calicivirus Antigen Combo Rapid Test
Product Overview
SaberVet FHV/FCV Ag Combo is a 2-in-1 rapid diagnostic panel for the simultaneous screening of Feline Herpesvirus and Calicivirus from a single sample.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation & species
- FHV/FCV Ag; cat
- Targets
- Feline herpesvirus antigen, feline calicivirus antigen; two independent test units
- Specimen
- Ocular, nasal or oral secretions
- Sample loading
- From the same extract, 3 drops (about 90 μL) into each of the two wells
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Pack size & storage
- 10 tests; store sealed at 4–30°C away from light, do not freeze
- Operating temperature
- 15–30°C
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
5 steps from the instructions for use
-
1Prepare the buffer
At 15–30°C, check the packaging, expiry date and sample ID, then open the buffer tube and place it in the workstation.
-
2Collect the sample
Use the swab provided to collect ocular, nasal or oral secretions from the cat, then place it in the buffer tube.
-
3Extract the sample
Rotate the swab in the buffer more than 10 times to release the sample, then close the cap.
-
4Load both wells
Add 3 drops of the mixture (about 90 μL) to each of the FHV and FCV wells, then start timing.
-
5
Read each result
Within 5–10 minutes, confirm both C lines, then read each T line. Record the FHV and FCV results; results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare the buffer At 15–30°C, check the packaging, expiry date and sample ID, then open the buffer tube and place it in the workstation.
- 2. Collect the sample Use the swab provided to collect ocular, nasal or oral secretions from the cat, then place it in the buffer tube.
- 3. Extract the sample Rotate the swab in the buffer more than 10 times to release the sample, then close the cap.
- 4. Load both wells Lay the cassette flat right after opening. Identify the FHV and FCV S wells and add the same mixture vertically into each, 3 drops (about 90 μL) per well, 6 drops in total. Start timing after loading each unit and do not skip either well.
- 5. Read each result Within 5–10 minutes, confirm both C lines, then read each T line. Record the FHV and FCV results; results after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use
The line patterns below apply to the FHV and FCV units separately; match results to the target labels on the cassette.

Positive
Both C and T lines appear in that unit; any visible T line is positive.

Negative
Only the C line appears in that unit: the detection level was not reached; further testing is needed when clinical suspicion is high.

Invalid
No C line in that unit: invalid whatever the T line shows.
Interpretation notes
- Invalid: No C line in that unit: invalid whatever the T line shows. Read the other unit by its own C/T lines and retest the invalid item with a new cassette.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| FHV | PCR | 96.00% 192/200 95% CI 92.31%–97.96% | 98.33% 295/300 95% CI 96.16%–99.29% | 97.40% 487/500 95% CI 95.60%–98.47% |
| FCV | PCR | 97.00% 97/100 95% CI 91.55%–98.97% | 99.20% 248/250 95% CI 97.13%–99.78% | 98.57% 345/350 95% CI 96.70%–99.39% |
Each target is evaluated separately against its reference method; the results are not combined into a single accuracy figure for the whole test.
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Dual-test cassettes
- Sampling swabs
- Buffer tubes
- Instructions for use
- Workstation
Also required
Timer, sample labels, gloves and waste container