SaberVet Logo
FHV_FCV Ag
GMP Certified
A Specialized Brand by ITGen

Sabervet Feline Herpesvirus/Calicivirus Antigen Combo Rapid Test

The SaberVet FHV/FCV Ag Combo test streamlines the diagnostic process for Feline Respiratory Disease Complex (FRDC). By providing dual-antigen detection on one device, it reduces both testing time and costs for feline clinics. SaberVet technology maintains high performance across both channels, with a total agreement of 98.57% for FCV. This professional combo kit allows for more comprehensive patient assessments during initial consultations, enabling targeted therapeutic strategies to be initiated without waiting for external lab results.
Specimen
Ocular, nasal or oral secretions
Pack Size
10 tests
Reading Time
5–10 minutes
Shelf Life
See the expiration date on the package.

Product Overview

SaberVet FHV/FCV Ag Combo is a 2-in-1 rapid diagnostic panel for the simultaneous screening of Feline Herpesvirus and Calicivirus from a single sample.

Technical Data

Product Parameters

Engineered for precision, built for reliability

Abbreviation & species
FHV/FCV Ag; cat
Targets
Feline herpesvirus antigen, feline calicivirus antigen; two independent test units
Specimen
Ocular, nasal or oral secretions
Sample loading
From the same extract, 3 drops (about 90 μL) into each of the two wells
Reading time
5–10 minutes; results after 15 minutes are invalid
Pack size & storage
10 tests; store sealed at 4–30°C away from light, do not freeze
Operating temperature
15–30°C
Shelf Life
See the expiration date on the package.
Certifications
CE, ISO 13485 & GMP certified
OEM/ODM Service
Available

Test Procedure

5 steps from the instructions for use

  1. Step 1: Prepare the buffer
    1

    Prepare the buffer

    At 15–30°C, check the packaging, expiry date and sample ID, then open the buffer tube and place it in the workstation.

  2. Step 2: Collect the sample
    2

    Collect the sample

    Use the swab provided to collect ocular, nasal or oral secretions from the cat, then place it in the buffer tube.

  3. Step 3: Extract the sample
    3

    Extract the sample

    Rotate the swab in the buffer more than 10 times to release the sample, then close the cap.

  4. Step 4: Load both wells
    4

    Load both wells

    Add 3 drops of the mixture (about 90 μL) to each of the FHV and FCV wells, then start timing.

  5. 5

    Read each result

    Within 5–10 minutes, confirm both C lines, then read each T line. Record the FHV and FCV results; results after 15 minutes are invalid.

Full step-by-step instructions
  1. 1. Prepare the buffer At 15–30°C, check the packaging, expiry date and sample ID, then open the buffer tube and place it in the workstation.
  2. 2. Collect the sample Use the swab provided to collect ocular, nasal or oral secretions from the cat, then place it in the buffer tube.
  3. 3. Extract the sample Rotate the swab in the buffer more than 10 times to release the sample, then close the cap.
  4. 4. Load both wells Lay the cassette flat right after opening. Identify the FHV and FCV S wells and add the same mixture vertically into each, 3 drops (about 90 μL) per well, 6 drops in total. Start timing after loading each unit and do not skip either well.
  5. 5. Read each result Within 5–10 minutes, confirm both C lines, then read each T line. Record the FHV and FCV results; results after 15 minutes are invalid.

Reading the Results

Read within the time stated in the instructions for use

The line patterns below apply to the FHV and FCV units separately; match results to the target labels on the cassette.

Positive result

Positive

Both C and T lines appear in that unit; any visible T line is positive.

Negative result

Negative

Only the C line appears in that unit: the detection level was not reached; further testing is needed when clinical suspicion is high.

Invalid result

Invalid

No C line in that unit: invalid whatever the T line shows.

Interpretation notes
  • Invalid: No C line in that unit: invalid whatever the T line shows. Read the other unit by its own C/T lines and retest the invalid item with a new cassette.

Performance Data

Method comparison results stated in the instructions for use

Target Reference Method Positive AgreementNegative AgreementOverall Agreement
FHV PCR 96.00% 192/200 95% CI 92.31%–97.96% 98.33% 295/300 95% CI 96.16%–99.29% 97.40% 487/500 95% CI 95.60%–98.47%
FCV PCR 97.00% 97/100 95% CI 91.55%–98.97% 99.20% 248/250 95% CI 97.13%–99.78% 98.57% 345/350 95% CI 96.70%–99.39%

Each target is evaluated separately against its reference method; the results are not combined into a single accuracy figure for the whole test.

Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.

Kit Contents

What is supplied in each box and what you need to prepare

Sabervet Feline Herpesvirus/Calicivirus Antigen Combo Rapid Test kit components

Included in the kit

  • Dual-test cassettes
  • Sampling swabs
  • Buffer tubes
  • Instructions for use
  • Workstation

Also required

Timer, sample labels, gloves and waste container

Request Information