Product Overview
The SaberVet FHW Ag Rapid Test offers a reliable solution for the qualitative detection of Feline Heartworm antigens. With a total agreement rate of 97.67%, this professional kit aids veterinarians in the early diagnosis of Dirofilaria immitis infections in cats.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation & species
- FHW Ag; cat
- Target & method
- Heartworm antigen; lateral flow immunoassay, visual qualitative reading
- Specimen
- Whole blood, serum or plasma
- Sample loading
- About 75 μL of blood premixed with buffer; 3 drops of mixture (about 90 μL) into the S well
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Pack size
- 10 tests per box
- Storage & operation
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
5 steps from the instructions for use
-
1Prepare the buffer
At 15–30°C, open the buffer tube, place it in the workstation and lay the cassette flat.
-
2Measure and transfer the blood
Use the volumetric dropper to draw the sample and transfer about 75 μL into the buffer tube.
-
3Mix the sample
Close the cap and shake gently to mix the blood with the buffer. Do not drop unmixed whole blood directly onto the cassette.
-
4Load and time
Add 3 drops of the mixture (about 90 μL) vertically into the S well, then start timing.
-
5
Read and record
Read the C/T lines within 5–10 minutes. Results after 15 minutes are invalid; do not use lines that appear later.
Full step-by-step instructions
- 1. Prepare the buffer Work at 15–30°C. Check the sample, lot and expiry date, open the buffer tube and place it in the workstation. Lay the cassette flat on a clean bench right after opening.
- 2. Measure and transfer the blood Squeeze the upper bulb of the volumetric dropper to draw whole blood, serum or plasma so that a little enters the lower bulb and the tube contains no air bubbles. Squeeze the upper bulb again to transfer about 75 μL of blood into the buffer tube.
- 3. Mix the sample Close the cap and shake gently to mix the blood with the buffer. Do not drop unmixed whole blood directly onto the cassette.
- 4. Load and time Add 3 drops of the mixture (about 90 μL) vertically into the S well, then start timing.
- 5. Read and record Read the C/T lines within 5–10 minutes. Results after 15 minutes are invalid; do not use lines that appear later.
Reading the Results
Read within the time stated in the instructions for use

Positive
Both colored C and T lines appear; a faint T line within the reading time is also positive.

Negative
Only the C line appears: the antigen was not detected at the test's detection level, but low worm burden, immature worms or male-only infection cannot be excluded.

Invalid
No C line appears: invalid whether or not a line appears in the T zone.
Interpretation notes
- Positive: Both colored C and T lines appear; a faint T line within the reading time is also positive. Heartworm antigen was detected in this blood sample; interpret with further veterinary examination.
- Invalid: No C line appears: invalid whether or not a line appears in the T zone. Check the sample, procedure and storage/transport, then retest with a new cassette.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| FHW Ag | PCR | 96.67% 116/120 95% CI 91.69%–99.08% | 98.33% 177/180 95% CI 95.21%–99.65% | 97.67% 293/300 95% CI 95.25%–99.06% |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Volumetric droppers
- Buffer tubes
- Instructions for use
- Workstation
Also required
Timer, suitable blood collection supplies, sample containers and personal protective equipment