Product Overview
The SaberVet FCoV Ag Rapid Test is an essential tool for monitoring feline health, offering a 98.25% total agreement with PCR methods. It allows for the fast, qualitative detection of Feline Coronavirus antigens in clinical environments.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation & species
- FCoV Ag; cat
- Target & method
- Feline coronavirus antigen; colloidal gold immunochromatography, visual qualitative reading
- Specimen
- Fresh feces, rectal swab or ascites
- Sample loading
- Feces/swabs: extract in buffer; ascites: add about 30 μL to the buffer. After mixing, add 3 drops (about 90 μL) to the S well
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Pack size
- 10 tests per box
- Storage & operation
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
7 steps from the instructions for use
-
1Prepare
At 15–30°C, open the buffer tube, place it in the workstation and lay a new cassette flat.
-
2AFeces or rectal swabCollect the fecal sample
Use the swab provided to collect fresh feline feces, or take a fecal sample from the rectum.
-
3AFeces or rectal swabExtract the sample
Place the swab in the buffer, rotate more than 10 times, then close the cap.
-
2BAscitesAdd the ascites
Use the dropper provided to add 1 drop (about 30 μL) of collected ascites to the buffer tube.
-
3BAscitesMix the ascites
Close the cap and shake the extraction tube gently to mix the ascites with the buffer.
-
4Load the cassette
Add 3 drops of the pre-treated mixture (about 90 μL) to the S well.
-
5
Time and read
Start timing after loading; read and record within 5–10 minutes. Results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare At 15–30°C, check the cat, product, lot and expiry date and that the packaging is intact. Open the buffer tube and place it in the workstation. Use the cassette right after opening, laid flat on a clean bench.
- 2A. Collect the fecal sample Use the swab provided to collect fresh feline feces, or take a fecal sample from the rectum.
- 3A. Extract the sample Place the swab in the buffer, rotate more than 10 times, then close the cap.
- 2B. Add the ascites Use the dropper provided to add 1 drop (about 30 μL) of collected ascites to the buffer tube.
- 3B. Mix the ascites Close the cap and shake the extraction tube gently to mix the ascites with the buffer.
- 4. Load the cassette After the matching pre-treatment, add 3 drops of the mixture (about 90 μL) vertically into the S well. Do not add unmixed ascites or feces directly.
- 5. Time and read Start timing after loading; read and record within 5–10 minutes. Results after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use

Positive
Both colored C and T lines appear; a faint T line within the reading time is also positive.

Negative
Only the C line appears: the antigen was not detected at the test's detection level; low-level or intermittent shedding cannot be excluded, and a negative alone does not rule out FIP.

Invalid
No C line appears: invalid with or without a T line. Check the sample, extraction, loading and storage/transport, then retest with a new cassette.
Interpretation notes
- Positive: Both colored C and T lines appear; a faint T line within the reading time is also positive. The antigen was detected in this sample; this alone does not confirm FIP.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| FCoV Ag | PCR | 98.50% 197/200 95% CI 95.48%–99.69% | 98.00% 196/200 95% CI 94.79%–99.40% | 98.25% 393/400 95% CI 96.36%–99.22% |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Sampling swabs
- Buffer tubes
- Disposable droppers
- Instructions for use
- Workstation
Also required
Timer, suitable sampling supplies and personal protective equipment. Ascites should be collected by a professional.