SaberVet Logo
FCV Ag
GMP Certified
A Specialized Brand by ITGen

Sabervet Feline Calicivirus Antigen Rapid Test

Positive Agreement
97.00%
Negative Agreement
99.20%
Reading Time
5–10 minutes
Shelf Life
See the expiration date on the package.

Product Overview

As a leading solution for feline health, SaberVet FCV Ag offers an impressive diagnostic negative agreement of 99.20%, minimizing false positives in critical care environments. This rapid test identifies Feline Calicivirus (FCV) antigens using ocular or nasal swabs with a 10-minute turnaround. SaberVet products are designed with high-affinity antibodies to ensure accuracy even in low-viral-load specimens. This kit supports veterinarians in providing evidence-based care and effectively managing the "cat flu" complex in multi-cat households or facilities.

Technical Data

Product Parameters

Engineered for precision, built for reliability

Abbreviation & species
FCV Ag; cat
Target & method
Feline calicivirus antigen; lateral flow immunoassay, visual qualitative reading
Specimen
Ocular discharge, nasal discharge or saliva/oral secretions
Extraction & loading
Rotate the swab in buffer more than 10 times; 3 drops of mixture (about 90 μL) into the S well
Reading time
5–10 minutes; results after 15 minutes are invalid
Pack size
10 tests per box
Storage & operation
Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
Shelf Life
See the expiration date on the package.
Certifications
CE, ISO 13485 & GMP certified
OEM/ODM Service
Available

Test Procedure

5 steps from the instructions for use

  1. Step 1: Prepare the buffer
    1

    Prepare the buffer

    Check the product, lot, expiry date and packaging, and work at 15–30°C. Open the buffer tube provided and place it securely in the workstation.

  2. Step 2: Collect secretions
    2

    Collect secretions

    Use the swab provided to collect secretions from the chosen ocular, nasal or oral site, and note the site and side.

  3. Step 3: Extract the sample
    3

    Extract the sample

    Place the swab in the buffer and rotate more than 10 times to release the sample, then close the cap tightly.

  4. Step 4: Load and time
    4

    Load and time

    Lay the cassette flat, add 3 drops of the mixture (about 90 μL) to the S well and start timing.

  5. 5

    Read and record

    Read the C/T lines within 5–10 minutes and record the result with a photo of the whole cassette. Results after 15 minutes are invalid.

Full step-by-step instructions
  1. 1. Prepare the buffer Check the product, lot, expiry date and packaging, and work at 15–30°C. Open the buffer tube provided and place it securely in the workstation.
  2. 2. Collect secretions Use the swab provided to collect secretions from the chosen ocular, nasal or oral site, and note the site and side.
  3. 3. Extract the sample Place the swab in the buffer and rotate more than 10 times to release the sample, then close the cap tightly.
  4. 4. Load and time Lay the cassette flat right after opening, add 3 drops of the mixed sample (about 90 μL) vertically into the S well and start timing. Do not add water, substitute the buffer or keep adding drops.
  5. 5. Read and record Read the C/T lines within 5–10 minutes and record the result with a photo of the whole cassette. Results after 15 minutes are invalid.

Reading the Results

Read within the time stated in the instructions for use

Positive result

Positive

Both colored C and T lines appear; a faint T line within the reading time is also positive.

Negative result

Negative

Only the C line appears: the antigen was not detected at the test's detection level; consider sampling quality, site, disease course and clinical signs.

Invalid result

Invalid

No C line appears: invalid whether or not a line appears in the T zone.

Interpretation notes
  • Positive: Both colored C and T lines appear; a faint T line within the reading time is also positive. The antigen was detected in this sample; this does not indicate viral load, strain virulence or the sole cause.
  • Invalid: No C line appears: invalid whether or not a line appears in the T zone. Check the sample, extraction, loading and storage/transport, then retest with a new cassette.

Performance Data

Method comparison results stated in the instructions for use

Target Reference Method Positive AgreementNegative AgreementOverall Agreement
FCV Ag PCR 97.00% 97/100 95% CI 91.17%–99.35% 99.20% 248/250 95% CI 96.94%–99.97% 98.57% 345/350 95% CI 96.60%–99.49%

Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.

Kit Contents

What is supplied in each box and what you need to prepare

Sabervet Feline Calicivirus Antigen Rapid Test kit components

Included in the kit

  • Test cassettes
  • Sampling swabs
  • Buffer tubes
  • Instructions for use
  • Workstation

Also required

Timer, sample labels and personal protective equipment

Request Information

Submitting...