Sabervet Feline Anaplasma Antibody Rapid Test
Product Overview
Sabervet Feline Anaplasma Antibody Rapid Test (F.ANA Ab) is a reliable lateral flow immunoassay designed for veterinary professionals. It enables qualitative detection of specific antibodies against Feline Anaplasma in feline serum, plasma, or whole blood samples, aiding in the determination of F.ANA infection. With positive agreement (97.22%) and negative agreement (96.97%), this test delivers accurate results within 5-10 minutes. The kit includes all necessary components—test devices, buffer, workstation, quantitative droppers, and a package insert—ensuring convenient on-site operation. Stored at 4-30℃ (no freezing), it maintains stability until the expiry date. Compliant with safety standards, it requires no special equipment, making it ideal for clinics, animal hospitals, and diagnostic labs seeking efficient feline infection screening.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation & species
- F.ANA Ab; cat
- Target & method
- Anaplasma antibodies; lateral flow immunoassay, visual qualitative reading
- Specimen
- Whole blood, serum or plasma
- Sampling & loading
- 75 μL of blood premixed in buffer; 3 drops of the mixture (about 90 μL) into the S well
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Pack size
- 10 tests per box
- Storage & operation
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
5 steps from the instructions for use
-
1Prepare the buffer
At 15–30°C, check the sample ID, product lot, expiry date and packaging. Open the buffer tube provided and place it in the workstation.
-
2Measure and transfer the blood
Use the volumetric dropper to draw blood and transfer about 75 μL into the buffer tube.
-
3Mix the sample
Close the buffer tube tightly and shake gently to mix the blood with the buffer.
-
4Load and time
Lay the cassette flat, add 3 drops of the mixture (about 90 μL) to the S well and start timing.
-
5
Read and record
Read and record the C/T lines within 5–10 minutes. Results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare the buffer At 15–30°C, check the sample ID, product lot, expiry date and packaging. Open the buffer tube provided and place it in the workstation.
- 2. Measure and transfer the blood Squeeze the upper bulb of the volumetric dropper to draw blood until the lower tube is full with no bubbles and a little liquid enters the lower bulb. Squeeze the upper bulb again to add about 75 μL of blood to the buffer tube; do not squeeze the lower bulb to expel the excess.
- 3. Mix the sample Close the buffer tube tightly and shake gently to mix the blood with the buffer.
- 4. Load and time Lay the cassette flat on a clean, level surface right after opening, add 3 drops of the mixture (about 90 μL) vertically into the S well and start timing. Do not add unmixed whole blood to the cassette.
- 5. Read and record Read and record the C/T lines within 5–10 minutes. Results after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use

Positive
Both colored C and T lines appear; a faint T line within the reading time is also positive.

Negative
Only the C line appears: the antibodies were not detected at the test's detection level; cats in the acute early phase or at high risk may still need further testing.

Invalid
No C line appears: invalid whether or not a line appears in the T zone.
Interpretation notes
- Positive: Both colored C and T lines appear; a faint T line within the reading time is also positive. Antibodies were detected; the test does not measure titer or indicate disease severity.
- Invalid: No C line appears: invalid whether or not a line appears in the T zone. Check the sample, premixing, loading, storage and timing, then retest with a new cassette.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| F.ANA Ab | ELISA | 97.22% 175/180 95% CI 93.48%–98.99% | 96.97% 160/165 95% CI 92.91%–98.89% | 97.10% 335/345 95% CI 94.68%–98.49% |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Volumetric droppers
- Buffer tubes
- Instructions for use
- Workstation
Also required
Timer, suitable blood collection supplies, sample containers and personal protective equipment