SaberVet Logo
Sabervet Canine Heartworm Antigen/Ehrlichia/Anaplasma/Babesia Gibsoni/Babesiosis Antibody Combo Rapid Test
GMP Certified
A Specialized Brand by ITGen

Sabervet Canine Heartworm Antigen/Ehrlichia/Anaplasma/Babesia Gibsoni/Babesiosis Antibody Combo Rapid Test

For qualitative detection of canine heartworm antigen and Ehrlichia, Anaplasma, Babesia gibsoni and Babesia canis antibodies in canine whole blood, serum or plasma. About 75 μL of blood is premixed with the buffer provided and loaded into five S wells, giving five independent results within 5–10 minutes for first-line screening of vector-borne and blood pathogens.
Specimen
Canine whole blood, serum or plasma
Pack Size
10 tests per box (five targets per test)
Reading Time
5–10 minutes
Technical Data

Product Parameters

Engineered for precision, built for reliability

Abbreviation & species
CHW Ag/EHR/ANA/BG/BC Ab; dog
Antigen target
CHW: canine heartworm antigen
Antibody targets
EHR: Ehrlichia; ANA: Anaplasma; BG: Babesia gibsoni; BC: Babesia canis
Method & specimen
Colloidal gold immunochromatography, visual qualitative reading; canine whole blood, serum or plasma
Sampling & loading
About 75 μL of blood mixed in buffer; 3 drops of mixture (about 90 μL) into each of the five S wells
Pack size
10 tests per box (five targets per test)
Reading time
5–10 minutes; results after 15 minutes are invalid
Storage & operation
Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C

Clear Results, Confident Diagnosis

Eliminate diagnostic uncertainty with our advanced colloidal gold technology that delivers crystal-clear test lines and reliable results every time.

SaberVet Advantage

Clear SaberVet test results
  • Deep red, crystal-clear T-lines
  • Clean, interference-free background
  • GMP-controlled batch consistency
  • Confident, reliable diagnosis

Test Procedure

5 steps from the instructions for use

  1. Step 1: Prepare the buffer
    1

    Prepare the buffer

    Open the buffer tube provided and place it in the workstation.

  2. Step 2: Draw a measured sample
    2

    Draw a measured sample

    Use the volumetric dropper to draw blood and transfer about 75 μL into the buffer.

  3. Step 3: Mix
    3

    Mix

    Close the cap and shake the extraction tube gently to mix the blood with the buffer.

  4. Step 4: Load all five wells
    4

    Load all five wells

    Add 3 drops of the mixture (about 90 μL) to each of the CHW, EHR, ANA, BG and BC wells.

  5. 5

    Time and read

    Start timing after loading and read the five windows within 5–10 minutes. Results after 15 minutes are invalid.

Full step-by-step instructions
  1. 1. Prepare the buffer Open the buffer tube provided and place it in the workstation.
  2. 2. Draw a measured sample Squeeze the upper bulb of the volumetric dropper to draw blood until the lower measuring tube is full and a little enters the lower bulb; make sure the tube has no air bubbles. Squeeze the upper bulb again to add about 75 μL of blood from the tube into the buffer.
  3. 3. Mix Close the cap and shake the extraction tube gently to mix the blood with the buffer.
  4. 4. Load all five wells Lay the cassette on a clean, level surface and add 3 drops of the mixture (about 90 μL) vertically into each of the CHW, EHR, ANA, BG and BC S wells. Do not add whole blood directly, and do not split 3 drops across the five wells.
  5. 5. Time and read Start timing after loading and read the five windows within 5–10 minutes; note separate start times if wells were loaded far apart. Results after 15 minutes are invalid.

Reading the Results

Read within the time stated in the instructions for use

Check the C/T lines window by window and record CHW Ag, EHR Ab, ANA Ab, BG Ab and BC Ab separately, noting the difference between antigen and antibody results.

Positive result

Positive

Both C and T lines appear; a faint colored T line within the reading time is also positive.

Negative result

Negative

Only the C line appears: the corresponding antigen or antibody was not detected at the test's detection level; early infection and other factors can still give a negative result.

Invalid result

Invalid

No C line appears: that item is invalid and is not recorded as negative.

Interpretation notes
  • Positive: Both C and T lines appear; a faint colored T line within the reading time is also positive. CHW indicates antigen detected; the other four indicate the corresponding antibodies, and an antibody positive alone does not establish active disease.
  • Invalid: No C line appears: that item is invalid and is not recorded as negative. Check the sample, volume and procedure and retest with a new cassette; if the shared sample or buffer was affected, retest all affected targets.

Performance Data

Method comparison results stated in the instructions for use

Target Reference Method Positive AgreementNegative AgreementOverall Agreement
CHW Ag PCR 98.00% 147/150 97.50% 156/160 97.74% 303/310
EHR Ab ELISA 98.50% 197/200 97.33% 146/150 98.00% 343/350
ANA Ab ELISA 98.13% 157/160 95.63% 153/160 96.88% 310/320
BG Ab ELISA 98.00% 147/150 97.33% 146/150 97.67% 293/300
BC Ab ELISA 98.00% 49/50 96.67% 145/150 97.00% 194/200

Each target is evaluated separately against its reference method; the results are not combined into a single accuracy figure for the whole test.

Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.

Kit Contents

What is supplied in each box and what you need to prepare

Sabervet Canine Heartworm Antigen/Ehrlichia/Anaplasma/Babesia Gibsoni/Babesiosis Antibody Combo Rapid Test kit components

Included in the kit

  • Five-target cassettes
  • Volumetric droppers
  • Buffer tubes
  • Instructions for use
  • Workstation

Also required

Timer, blood collection supplies and personal protective equipment

Request Information