Sabervet Canine Rotavirus Antigen Combo Rapid Test
Product Overview
Rapidly identify Canine Rotavirus with the SaberVet CRV Ag test, a vital tool for preventing the spread of infection in clinics and shelters. This kit is engineered for high performance, showing excellent agreement with PCR results. The procedure is straightforward: collect a sample via swab, mix with the extraction buffer, and apply to the test cassette. It is designed specifically for canine use, ensuring negative agreement (97.87%) and minimal false results. Packaged for professional use, the components are stable at room temperature and come with clear instructions for easy implementation.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation
- CRV Ag
- Species
- Dog
- Targets
- Canine rotavirus antigen
- Format
- Single-target immunochromatographic qualitative cassette
- Specimen
- Fresh feces or rectal swab
- Pack size
- 10 tests per box
- Sample volume
- 3 drops of extracted mixture (about 90 μL)
- Reading time
- 5–10 minutes; results after 15 minutes are invalid
- Storage & test temperature
- Store sealed at 4–30°C away from light, do not freeze; test at 15–30°C
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
5 steps from the instructions for use
-
1Prepare the buffer
Open the buffer tube and place it in the workstation.
-
2Collect the sample
Swab a small amount of fresh feces or collect a rectal sample, then place the swab in the buffer.
-
3Extract the sample
Rotate the swab in the buffer more than 10 times, then close the dropper cap.
-
4Sample loading
Lay the cassette flat and add 3 drops of the mixture (about 90 μL) to the S well.
-
5
Time and read
Start timing after loading; read and record at 5–10 minutes. Results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare the buffer Open the buffer tube and place it in the workstation.
- 2. Collect the sample Use the swab provided to take a small amount of fresh feces, or have trained staff collect a rectal sample, then place the swab in the buffer.
- 3. Extract the sample Rotate the swab in the tube more than 10 times to release the sample; remove the swab and close the tube with the dropper cap.
- 4. Sample loading Open the foil pouch and lay the cassette on a clean, level surface. Add 3 drops of the mixture (about 90 μL) vertically into the S well.
- 5. Time and read Start timing after loading; read and record at 5–10 minutes. Results after 15 minutes are invalid.
Reading the Results
Read within the time stated in the instructions for use

Positive
Both C and T lines appear; a faint T line is also positive.

Negative
Only the C line appears: rotavirus antigen was not detected at the test's detection level. Low antigen, uneven sampling or improper handling can still affect detection.

Invalid
No C line appears: invalid whether or not a T line appears. Investigate, then retest with a new cassette.
Interpretation notes
- Invalid: No C line appears: invalid whether or not a T line appears. Investigate, then retest with a new cassette. T-line intensity is not used to estimate viral load, infectivity or severity. Interpret both positive and negative results with the history, signs and other tests.
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Positive Agreement | Negative Agreement | Overall Agreement |
|---|---|---|---|---|
| CRV Ag | PCR | 98.46% 64/65 | 97.87% 46/47 | 98.21% 110/112 |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Sampling swabs
- Buffer tubes
- Instructions for use
- Workstation
Also required
Timer