Product Overview
The SaberVet CDV Ag Rapid Test is a high-accuracy lateral flow immunoassay designed for the detection of Canine Distemper Virus antigen in canine eye, nasal fluid, or saliva samples. It provides crucial diagnostic support for veterinarians with results available in just 5-10 minutes.
Product Parameters
Engineered for precision, built for reliability
- Abbreviation
- CDV Ag
- Species
- Dog
- Targets
- Canine distemper virus antigen
- Format
- Single-target colloidal gold immunochromatographic qualitative cassette
- Specimen
- Ocular discharge, nasal discharge or saliva
- Sample volume
- 3 drops of the extracted sample (about 90 μL)
- Reading time
- 5–10 minutes after loading; results after 15 minutes are invalid
- Pack size
- 10 tests (10 cassettes per box)
- Storage
- 4–30°C, sealed and protected from light, do not freeze
- Shelf Life
- See the expiration date on the package.
- Certifications
- CE, ISO 13485 & GMP certified
- OEM/ODM Service
- Available
Test Procedure
5 steps from the instructions for use
-
1Prepare the buffer
Open the extraction tube containing buffer and place it securely in the workstation.
-
2Collect the sample
Use the swab provided to collect ocular, nasal or oral secretions.
-
3Extract the sample
Rotate the swab in the buffer more than 10 times, then close the dropper cap.
-
4Load and time
Lay the cassette flat, add 3 drops of extract (about 90 μL) to the S well and start timing.
-
5
Read and record
Read the C and T lines 5–10 minutes after loading. Results after 15 minutes are invalid.
Full step-by-step instructions
- 1. Prepare the buffer Open the extraction tube containing buffer and place it securely in the workstation.
- 2. Collect the sample Use the swab provided to collect the dog's ocular, nasal or oral secretions. Do not touch the swab tip; use a separate set of sampling and test consumables for each animal.
- 3. Extract the sample Place the swab in the buffer tube and rotate more than 10 times so the sample enters the buffer. Remove the swab and close the dropper cap.
- 4. Load and time Take the cassette out of the foil pouch and lay it on a clean, level bench. Add 3 drops of the extracted sample (about 90 μL) vertically into the sample well (S) and start timing.
- 5. Read and record Observe the C and T lines 5–10 minutes after loading and record the result. Results after 15 minutes are invalid; do not use changes that appear later.
Reading the Results
Read within the time stated in the instructions for use

| Line pattern | Result | Meaning |
|---|---|---|
| C and T lines both appear | Positive | Target antigen detected at this method's detection level; any T line within the reading time counts as positive. |
| Only the C line appears | Negative | Target antigen not detected at the detection level in this sample; infection cannot be fully excluded. |
| No C line, with or without a T line | Invalid | Do not report; check the sample and procedure and retest with a new cassette. |
Performance Data
Method comparison results stated in the instructions for use
| Target | Reference Method | Sensitivity | Specificity | Overall Agreement |
|---|---|---|---|---|
| CDV Ag | PCR | 96.67% 145/150 | 97.33% 146/150 | 97.00% 291/300 |
Figures reflect the study samples and reference methods described in the instructions for use. Interpret individual results together with clinical findings.
Kit Contents
What is supplied in each box and what you need to prepare

Included in the kit
- Test cassettes
- Sampling swabs
- Buffer tubes
- Instructions for use
- Workstation
Also required
Timer